ST-336 Pipeline & Cable Locator

ST-336 Pipeline & Cable Locator

336 Pipeline & Cable Locators scan the ground and use radio frequency signal to locate Pipe & Cable. The Pipeline & Cable Locator consists of two basic units: a directional radio frequency transmitter and a receiver. We utilize the principle of electromagnetism .The electromagnetic method is a

Specifications

Pipeline & Cable Locator


The ST-336 Pipeline & Cable Locator is designed for the underground utilities route locating, the depth measuring and distance tracing.

The multi-coil electromagnetism technology is adopted to enhance the capability of pipeline/cable locating, depth measurement and recognition. A distance trace of the pipeline/cable can be recorded to spot the pipeline/cable from the crowded complex. It is widely used in the telecommunication, electric, tap water, natural gas and physical prospecting.

Our Pipeline & Cable Locators scan the ground and use radio frequency signal to locate Pipe & Cable. The Pipeline & Cable Locator consists of two basic units: a
directional radio frequency transmitter and a receiver. We utilize the principle of electromagnetism .The electromagnetic method is a well-test and most popular method in underground utility survey function : to detect underground cable/pipe/position and depth; to locate position of hidden /pipe.

 
Transmitter
Technical specification of Transmitter:
Signal frequency
Router and depth mode            480Hz, 30.72 KHz
Induct mode                              30.72 KHz
Output Pressure                        0-500 VP-P automatic/manual adjustment due
                                                     to the insulated instance
Output wave shape                   sine wave
Power source                             12 VDC 4.5 AH in the Ni-MH cell
Peak output power                    10W
Inductive clamp                          30.72 KHz
 
Receiver
Technical specification of Receiver:
Power loss                       1W
Power source                     12 VDC 1.5AH in the Ni-MH cell or 10 alkalescency batteries
Biggest test burying depth        4.5 meters (normal instance)
The best burying depth error           0.05h5cm(h is pipeline depth)
The test route error            5cm(normal condition)
The test insulated error          25M
Test the route and the efficient depth with Inject method 20Km(normal instance)
Test the route and the efficient depth with Induct method 3Km(normal instance)
Note:
The objective pipeline has no insulated failure or other interruption in the
above-mentioned range in the normalinstances.
 
Environmental request
Operating temperature            - 20 ~ + 50
Storage temperature              -40 ~ + 70
Relative humidity                 10%~90%
Atmospheric pressure             86~106KPa
Environment noise                60dB